- Model: BAL-PIN300
- Capacity: 300 g
- Resolution: 0.001 g
- Min Weighing: 0.004 g
- Repeat Ability: ±0.002 g
0.0001g Analytical Weighing Balance, Internal Calibration
Warning: call_user_func_array() expects parameter 1 to be a valid callback, function 'wpb_pcf_contact_form_button' not found or invalid function name in /www/wwwroot/www.labpeak.com/wp-includes/class-wp-hook.php on line 341
0.0001 Analytical Weighing Balance Feature:
- Equipped with an electromagnetic sensor for high-precision measurement.
- Durable aluminum housing with a spacious draft shield to reduce airflow interference.
- Clear LCD display with white backlight and black characters for easy reading.
- Supports tare, counting, and multiple unit conversions (g, mg, ct, oz, etc.).
- Adjustable sensitivity and speed, with percentage weighing function.
- Built-in alerts for overload and system errors, along with a level indicator.
- Optional features include under-weighing function and external printer support.
0.0001g Analytical Weighing Balance Specification:
| Model | BAL-PIN300 |
| Capacity | 300 g |
| Resolution | 0.001 g |
| Min weighing | 0.004 g |
| Repeat ability | ±0.002 g |
| Liner | ±0.003 g |
| Stable Time | ≤3 s |
| Pan size | Φ80 mm |
| Display | LCD (white backlight with black font) |
| Temperature | 15-35 ℃ |
| Draft shield size | 240×190×265mm |
| Inter Size | 340×215×350mm |
| Option | Printer/Under weighing |
| Calibration | Internal Calibration |
| Cal.weight | Internal Calibration+Weight 200g |
| Interface | RS232C (Standard); USB/Printer (Option) |
| Packing Size | In:415×285×430 mm; Ex:475×315×485 mm |
| N.W/G.W (kg) | 10/11 |
Different between external calibration vs internal calibration
The difference between external calibration and internal calibration in a weighing balance is mainly in method, convenience, and accuracy control:
External Calibration:
Method: Uses certified external weights placed manually on the balance
Operation: Requires user intervention
Flexibility: Can verify accuracy across different weight ranges
Cost: Lower (no built-in calibration system)
Application: Suitable for standard lab use and periodic verification
Internal Calibration:
Method: Uses built-in calibration weights inside the balance
Operation: Automatic or one-touch calibration
Convenience: Fast and easy, no external weights needed
Stability: Reduces human error and improves consistency
Cost: Higher due to integrated system
Application: Ideal for high-precision or frequent calibration needs
How should the balance be installed?
Install the balance on a firm, level surface with minimal vibration. Keep it away from airflow, sunlight, and heat sources. A dedicated weighing table is recommended, and proper leveling should be checked before operation.
Is it sensitive to environmental conditions?
Yes, changes in temperature, air movement, humidity, and vibration may affect accuracy. For optimal performance, use the balance in a stable and controlled environment.
Can it connect to external devices?
Yes, it can interface with devices such as computers or printers through communication ports, enabling data transfer, storage, and report printing.
How do I ensure accurate results?
Allow the unit to stabilize after powering on, calibrate regularly, and position samples at the center of the pan. Avoid direct contact with samples and reduce external disturbances during weighing.
WHY Labpeak
- 24 Months Limited Warranty
- CE & FDA Standards
- 1-2 Days Handling and 7-30 Days Shipping

Get Social