- Model : SPL-PAA4530
- Wavelength Range : 190-900nm
- Accuracy of the Wavelength : ±0.15nm
- Receptivity of the Wavelength : ≤0.04nm
- Size(W×D×H)(mm) : 730×625×700

Atomic Absorption Spectrophotometer
Warning: call_user_func_array() expects parameter 1 to be a valid callback, function 'wpb_pcf_contact_form_button' not found or invalid function name in /www/wwwroot/www.labpeak.com/wp-includes/class-wp-hook.php on line 341
Atomic Absorption Spectrophotometer Feature:
- Fully automated system with complete PC control.
- Floating optical platform enhances stability and vibration resistance.
- Burner height adjusts automatically for optimal performance.
- Supports preheating of eight lamps with auto selection.
- Automatic peak detection and wavelength scanning.
- Comprehensive safety system with alarms and protection functions.
- Self-absorption background correction with deuterium lamp adjustment.
- Advanced data processing capabilities.
Atomic Absorption Spectrophotometer Specifications:
| Model | SPL-PAA4530 |
| Wavelength Range | 190-900nm |
| Spectral Bandwidth | 0.1/0.2/0.4/1.0/2.0 nm |
| Accuracy of the Wavelength | ±0.15nm |
| Receptivity of the Wavelength | ≤0.04nm |
| Base Line Stability | ≤0.002A/30min (Cu) |
| Characteristic Viscosity | 0.02μg/ml/1% (Cu) |
| Checking Limit | 0.004μg/ml (Cu) |
| Preciseness | 0.005 |
| Grating | 1800 lines/mm |
| Inflamer | All-metal titanium burner |
| Atomizer | Effective glass atomizer |
| Lamp Stand | 8 |
| D2 Background Correction Ability | When the background is 1A, the background ability should be deducted not less than 50 times, self absorption background deduction method |
| Power Source | 220V±22V AC |
| Shipping Size(W×D×H)(mm) | 860×705×755(Main instrument) |
| 1170×645×900(Accessories) | |
| G.W. (kg) | 105 (Main instrument); 100 (Accessories) |
| Flame System | |
| Acetylene Air Burner | 100mm |
| Lgnition Dynamic Baseline Drift | ≤0.006A/30min |
| (Cu) Characteristic Viscosity | ≤0.025μg/ml/1% |
| Related Standard Deviation of the Accuracy | ≤0.5% (Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml) |
| Safety System | Can automatically cut off the gas when the pressure is not enough the power is off flame out and unconformity of the burner |
| Graphite Furnace | |
| The Highest Temperature | 3000℃ |
| The Largest Temperature Rising Speed | ≥2000℃/s |
| Characteristic Quantity | Cd≤0.5×10-12g Cu≤0.5×10-11g |
| Accuracy | Cu≤3% Cd≤3% |
| Size (mm) and Weight | 730×625×700; 79.3kg |
| Safety System | Over current protection |
| Low air pressure alarm/protection | |
| Low cooling water flow alarm/protection | |
| Power Source and Power | 220V±22V AC 7000W |
Atomic Absorption Spectrophotometer Packing:
This spectrophotometer is packed in a sturdy wooden case with foam lining, shock and impact resistant. Cooperate with reputable logistics companies to provide full tracking. Free repair or replacement for transport damage to ensure safe delivery.
WHY Labpeak
- 24 Months Limited Warranty
- CE & FDA Standards
- 1-2 Days Handling and 7-30 Days Shipping