Atomic Absorption Spectrophotometer

  • Model : SPL-PAA4530
  • Wavelength Range : 190-900nm
  • Accuracy of the Wavelength : ±0.15nm
  • Receptivity of the Wavelength : ≤0.04nm
  • Size(W×D×H)(mm) : 730×625×700

Share the product


Warning: call_user_func_array() expects parameter 1 to be a valid callback, function 'wpb_pcf_contact_form_button' not found or invalid function name in /www/wwwroot/www.labpeak.com/wp-includes/class-wp-hook.php on line 341

Atomic Absorption Spectrophotometer Feature:

  1. Fully automated system with complete PC control.
  2. Floating optical platform enhances stability and vibration resistance.
  3. Burner height adjusts automatically for optimal performance.
  4. Supports preheating of eight lamps with auto selection.
  5. Automatic peak detection and wavelength scanning.
  6. Comprehensive safety system with alarms and protection functions.
  7. Self-absorption background correction with deuterium lamp adjustment.
  8. Advanced data processing capabilities.

Atomic Absorption Spectrophotometer Specifications:

Model SPL-PAA4530
Wavelength Range 190-900nm
Spectral Bandwidth 0.1/0.2/0.4/1.0/2.0 nm
Accuracy of the Wavelength ±0.15nm
Receptivity of the Wavelength ≤0.04nm
Base Line Stability ≤0.002A/30min (Cu)
Characteristic Viscosity 0.02μg/ml/1% (Cu)
Checking Limit 0.004μg/ml (Cu)
Preciseness 0.005
Grating 1800 lines/mm
Inflamer All-metal titanium burner
Atomizer Effective glass atomizer
Lamp Stand 8
D2 Background Correction Ability When the background is 1A, the background ability should be deducted not less than 50 times, self absorption background deduction method
Power Source 220V±22V AC
Shipping Size(W×D×H)(mm) 860×705×755(Main instrument)
1170×645×900(Accessories)
G.W. (kg) 105 (Main instrument); 100 (Accessories)
Flame System
Acetylene Air Burner 100mm
Lgnition Dynamic Baseline Drift ≤0.006A/30min
(Cu) Characteristic Viscosity ≤0.025μg/ml/1%
Related Standard Deviation of the Accuracy ≤0.5% (Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)
Safety System Can automatically cut off the gas when the pressure is not enough the power is off flame out and unconformity of the burner
Graphite Furnace
The Highest Temperature 3000℃
The Largest Temperature Rising Speed ≥2000℃/s
Characteristic Quantity Cd≤0.5×10-12g Cu≤0.5×10-11g
Accuracy Cu≤3% Cd≤3%
Size (mm) and Weight 730×625×700; 79.3kg
Safety System Over current protection
Low air pressure alarm/protection
Low cooling water flow alarm/protection
Power Source and Power 220V±22V AC 7000W

Atomic Absorption Spectrophotometer Packing:

This spectrophotometer is packed in a sturdy wooden case with foam lining, shock and impact resistant. Cooperate with reputable logistics companies to provide full tracking. Free repair or replacement for transport damage to ensure safe delivery.

WHY Labpeak

  1. 24 Months Limited Warranty
  2. CE & FDA Standards
  3. 1-2 Days Handling and 7-30 Days Shipping

Title

CONTACT INFO

Liancheng Manufacturing Town, No. 19 Huanghe Street, Jinan City, Shandong Province, China

Go to Top