• Model: PCR-LP800;
    • Work Surface Height: 750mm
    • Available Sizes: 2 ft
    • Illuminating Lamp: 500 Lx
    • Airflow Velocity: ~0.2~0.5 m/s, Speed adjustable
    • Pre-Filter: 1pcs, Polyester fiber, washable
  • Our state-of-the-art PCR cabinet is designed to revolutionise your Polymerase Chain Reaction (PCR) workflow, providing a sterile and controlled environment for your critical experiments.
    • Model: PCR-LP1100; PCR-LP1300; PCR-LP1600; PCR-LP1900
    • Work Surface Height: 750mm
    • Illuminating: ≥900Lx
    • Airflow Velocity: 0.2~0.5 m/s, speed adjustable
    • Model: ADP-LP10000; ADP-LP10000I
    • Applicable Volume: ≤100m³
    • Working Time: ≥60 min
    • Filter: Pre-filter, HEPA filter
    • Air Speed Level: 1-3 adjustable
    • Model: DB-LP1000; DB-LP1300; DB-LP1500
    • Air Velocity: 0.38-0.58 m/s
    • Supply Air Volume: 1800/h; 2600/h; 3000/h
    • Exhaust Air Volume: 10%~15%
    • External Size(WxDxH)(mm): 1000x1350x2400; 1300x1350x2400; 1500x1350x2400
    • Model : PW-LP1800; PW-LP1800E
    • Work Surface Height(mm) : 870
    • Exhaust Airflow Volume : 1500-1800 m³/h (Full pressure range: 330-550pns)
    • Air Velocity : ≥0.8m/s
    • External Size (W×D×H)(mm) : 1800×800×2000; 1800×800×2350
    • Models: AS-LP1P1C; AS-LP1P2C; AS-LP2P2C
    • HEPA Filter: 99.995% efficiency at 0.3μm
    • Spraying Wind Speed: 25m/s
    • Air Shower Time: 0~99s (adjustable)
    • Sound Emission: <70db
    • Model : NE-LPM01
    • Nebulization Rate: ≥0.25 mL/min
    • Working Mode: Continuous working
    • Safety classification: Class II, type BF applied part
    • Models: ASPB-LP1; ASPB-LP2; ASPB-LP3; PB-LP1; PB-LP2; PB-LP3
    • Material: 304 Stainless steel
    • Interlock: Electronical
    • Clean Air Speed: 0.36~0.54m/s
    • HEPA Filter: Efficiency2 99.999% at 0.3μm
    • Model: MFE-LP240
    • Connection Inner Diameter for Exhaust duct: 90mm
    • Airflow Volume: 240m³/h
    • HEPA Filter: HEPA filter, ≥99.995% efficiency at 0.3 μm
    • Model: DLM-LP603
    • Resolution: 1 Lux/0.1FC
    • Sampling: 0.5sec
    • Temperature Range: -10~50 ℃ (14 to 122 ℉)
    • Temperature Accuracy: ±1 ℃
    • Humidity Range: 20%~90%RH
    • Model: DPC-LP330
    • Flow Rate: 28.3 L/min
    • Sampling Period: 1s–99 min 59 s
    • Self-Purification Time: ≤10 min
    • Flow Rate Error: ≤2%
    • Particle Size Distribution Error: ≤15%
    • Model: FFU-LP600; FFU-LP1200; FFU-LP1200Pro
    • Air Velocity: 0.45 m/s ± 20%
    • Filter: 1pcs Pre-filter, 1pc H14 HEPA filter
    • Efficiency: ≥99.995% efficiency at 0.3 μm
    • Model: HDA-LP40
    • Sensor: Type Hot bulb
    • Measurement Range: 0~2m/s or 0.~20m/s (Selectable)
    • Resolution: 0.01m/s
    • Detection Precision: ≤3%(Full Scale)
    • Model: LC-LPM01; LC-LPM27
    • Seat/back Material: PU
    • Height Adjustable Range: 42~54cm
    • Seat Size: Φ330mm; 485×425mm
    • Model : STL-PV35H; STL-PV50H; STL-PV75H; STL-PV100H
    • Capacity (L): 35, 50, 75, 100
    • Consumption (kW) : 2.5, 3, 4.5
    • Rated Working Pressure : 0.22 MPa
    • Rated WorkingTemperature : 134 ℃
    • Sterilization Temperature Setting Range : 105–134 ℃
    • Model: STL-PV35G; STL-PV50G; STL-PV75G; STL-PV100G
    • Capacity (L): 35, 50, 75, 100
    • Rated Working Pressure: 0.22 MPa
    • Rated Working Temperature: 134°C
    • Sterilization Temperature Setting Range: 116–134 °C
    • Sterilization Time Setting Range: 4–120 min