- Model: BAL-PE1005; BAL-PE1205; BAL-PE2005; BAL-PE2205
- Weight Sensor: Electromagnetic Force Compensation Sensor
- Readability: 0.0001 g
- Min. Weighing: 0.0004 g
- Repeatability: ±0.0002 g
- Linearity: ±0.0003 g
0.0001g Analytical Weighing Balance, External Calibration
Warning: call_user_func_array() expects parameter 1 to be a valid callback, function 'wpb_pcf_contact_form_button' not found or invalid function name in /www/wwwroot/www.labpeak.com/wp-includes/class-wp-hook.php on line 341
Equipped with an ultra-thin electromagnetic force sensor. The device achieves a miniaturized and lightweight weighing mechanism while maintaining sensitivity and stability, providing users with an accurate, rapid, and cost-effective weighing solution.
0.0001 Analytical Weighing Balance Feature:
- Ultra-thin electromagnetic force compensation sensor reduces the risk of damage during transit while simultaneously enhancing sensitivity and response speed.
- Spacious Draft Shield: Prevents reading drift caused by ambient air currents.
- Level Indicator provides a visual aid to help users quickly level the balance, ensuring that weighing operations are performed under optimal conditions.
- High-quality aluminum alloy housing that is robust, corrosion-resistant, and easy to clean, prolonging the service life.
- Integrates multiple practical functions, including Tare function, counting, and Unit conversion (g/mg/ct/oz), to streamline workflows and enhance efficiency.
- Intelligent peak-hold function locks and displays the maximum value recorded during the weighing process, enabling users to precisely capture critical data.
- Supports adjustment of display speed and stability, allowing users to flexibly configure parameters based on varying weighing environments and sample characteristics.
- Overload alarm function helps prevent equipment damage and weighing errors caused by operational errors.
0.0001g Analytical Weighing Balance Specification:
| Model | BAL-PE1005 | BAL-PE1205 | BAL-PE2005 | BAL-PE2205 |
| Max. Capacity (g) | 100 | 120 | 200 | 220 |
| Weight Sensor | Electromagnetic Force Compensation Sensor | |||
| Readability | 0.0001 g | |||
| Min. Weighing | 0.0004 g | |||
| Repeatability | ±0.0002 g | |||
| Linearity | ±0.0003 g | |||
| Settling Time | ≤3 s | |||
| Pan Size | Φ80 mm (Standard), Φ90 mm (Optional) | |||
| Display | LCD (white back light with black font) | |||
| Calibration | External Calibration | |||
| Calibration Weight (g) | 100×1 | 200×1 | ||
| Accessory | RS232C (Standard), Printer (Optional) | |||
| Ambient Temperature | 15–35 ℃ | |||
| Power Supply | 220/110 V, 50/60 Hz | |||
| Draft Shield Size | 180×175×200 mm | |||
| External Size (W×D×H) | 300×200×295 mm | |||
| Package Size (W×D×H) | 430×320×420 mm | |||
| N.W./G.W. | 5/6.5 kg | |||
Different between external calibration vs internal calibration
The difference between external calibration and internal calibration in a weighing balance is mainly in method, convenience, and accuracy control:
External Calibration:
Method: Uses certified external weights placed manually on the balance
Operation: Requires user intervention
Flexibility: Can verify accuracy across different weight ranges
Cost: Lower (no built-in calibration system)
Application: Suitable for standard lab use and periodic verification
Internal Calibration:
Method: Uses built-in calibration weights inside the balance
Operation: Automatic or one-touch calibration
Convenience: Fast and easy, no external weights needed
Stability: Reduces human error and improves consistency
Cost: Higher due to integrated system
Application: Ideal for high-precision or frequent calibration needs
How should the balance be installed?
Place the balance on a stable, level, and vibration-free surface. Keep it away from drafts, direct sunlight, and heat sources. It is recommended to use a dedicated weighing table and ensure proper leveling before use.
Is it sensitive to environmental conditions?
Yes, factors such as temperature fluctuations, air currents, humidity, and vibration can influence weighing results. For best performance, operate the balance in a controlled environment with minimal disturbances.
Can it connect to external devices?
Yes, the balance can be connected to external devices such as printers or computers via communication interfaces. This allows for convenient data transfer, recording, and report generation.
How do I ensure accurate results?
Allow sufficient warm-up time before use, perform regular calibration, and place samples carefully at the center of the pan. Avoid touching samples with bare hands and minimize environmental interference during measurement.
WHY Labpeak
- 24 Months Limited Warranty
- CE & FDA Standards
- 1-2 Days Handling and 7-30 Days Shipping