• Model : STL-PV35L; STL-PV50L; STL-PV75L; STL-PV100L; STL-PV120L; STL-PV150L
    • Capacity (L): 35, 50, 75, 100, 120, 150
    • Consumption (kW) : 2.5, 3, 4.5, 6
    • Rated Working Pressure : 0.22 MPa
    • Rated WorkingTemperature : 134 ℃
    • Sterilization Temperature Setting Range : 105–134 ℃
    • Model : STL-PV50V; STL-PV75V; STL-PV100V
    • Capacity (L): 50, 75, 100
    • Consumption (kW) 4.8, 5, 5.1
    • Rated Working Pressure : 0.22 MPa
    • Rated WorkingTemperature : 134 ℃
    • Sterilization Temperature Setting Range : 105–134 ℃
    • Model: STL-PBH1200PV; STL-PBH1500PV
    • Chamber Design Pressure: -0.1/0.3MPa
    • Jecket Design Pressure: 0.3MPa
    • Generator Design Pressure: 1.0MPa
    • Design Temperaure: 150℃
    • Model: STL-PBA650PV; STL-PBA800PV; STL-PBA1000PV; STL-PBA1200PV; STL-PBA1500PV;
    • Volume(L): 650 / 800 / 1000 / 1200 / 1500
    • Chamber Design Pressure: 0.3 MPa
    • Generator Design Pressure: 1.0 MPa
    • Design Temperature: 150℃
    • Model: STL-PBV150PV; STL-PBV180PV; STL-PBV250PV; STL-PBV300PV; STL-PBV360PV; STL-PBV450PV; STL-PBV600PV; STL-PBV800PV;
    • Volume(L): 150 / 180 / 250 / 300 / 360 / 450 / 600 / 800
    • Chamber Design Pressure: -0.1/0.3MPa
    • Generator Design Pressure: 1MPa
    • Design Temperature: 150℃
    • Model: STL-PH25AE; STL-PH50AE; STL-PH80AE; STL-PH100AE; STL-PH180AE
    • Shelves: 2
    • Capacity (L): 25 / 50 / 80 / 105 /180 L
    • Circulation: Forced air convection
    • Temperature Range: RT+10~250 ℃
    • Uniformity: ≤ Max operating temperature±2.5%
    • Model: TDOL-PN45D; TDOL-PN45; TDOL-PN70D; TDOL-PN70; TDOL-PN140D; TDOL-PN140; TDOL-PN220D; TDOL-PN270;
    • Capacity: 42 / 70 / 135 / 137 / 224 270
    • Circulation Mode: Natural convection
    • Temperature Range: 50~200 ℃
    • Timer: 0~9999 min
    • Model: IDOL-P70H; IDOL-P140H; IDOL-P270H
    • Temperature range: 50°C~250°C
    • Temperature uniformity: ≤ Max operating temperature ±3.5%
    • Temperature fluctuation: ±1°C
    • Model: DOIL-P50E; DOIL-P80E; DOIL-P150E; DOIL-P250E
    • Incubator: RT +5°C -80°C;
    • Drying oven: 80-200°C
    • Fluctuation: ±0.5 ℃
    • Uniformity Incubator: ≤ ±1 ℃;
    • Internal Circulation Method: Forced convection
    • Model: FDOL-P50N; FDOL-P110N; FDOL-P160N; FDOL-P50F; FDOL-P110F; FDOL-P160F;
    • Capacity: 50; 105; 155 L
    • Circulation Mode: Natural convection; Forced convection
    • Temperature Range: RT+5–230 °C; RT+5–250 °C
    • Temperature Uniformity: ±1.8 °C at 100 °C; ±2.8 °C at 150 °C
    • Model: WDL-P180; WDL-P360
    • Capacity (L): 180, 360
    • Display: 7-inch LCD touch screen
    • Standard Program: 4+30 units
    • Self-defined program: 200 units
    • Storage: One hundred thousand pieces of data
    • Model : RFZL-P40V310; RFZL-P40V450; RFZL-P40V620;
    • Cabinet: Refrigerator; Freezer
    • Temperature Range: 2 to 8 °C, -20 to -40 °C 
    • Sensor: NTC
    • Cooling Mode: Forced Air Cooling, Direct Cooling
    • Model : MRL-P5V410; MRL-P5V520; MRL-P5V540; MRL-P5V720; MRL-P5V1010;
    • Temperature Range: 2 to 8 ℃
    • Sensor: NTC
    • Temperature controller: Electronic
    • Cooling Mode: Air cooling
    • Defrost Mode: Auto defrost
    • Model: MRL-P5V150; MRL-P5V400; MRL-P5V460; MRL-P5V640; MRL-P5V800; MRL-P5V1150
    • Temperature Range: 2 to 8 ℃
    • Sensor: NTC
    • Temperature controller: Electronic
    • Cooling Mode: Forced Air Cooling
    • Model: FZL-P30V300; FZL-P30V500; FZL-P40V440; FZL-P40V590
    • Temperature Range: -10 to -30 °C, -20 to -40 °C
    • Sensor: NTC
    • Temperature Controller: Microcomputer Control
    • Cooling Mode: Direct Cooling
    • Defrost Mode: Manual
    • Model: FZL-P40H125; FZL-P40H260
    • Capacity (L): 125, 215
    • Temperature Range: -20 to -40 ℃
    • Accuracy: 1°C
    • Sensor: NTC
    • Temperature Controller: Electronic